{"id":415,"date":"2026-08-28T15:42:22","date_gmt":"2026-08-28T15:42:22","guid":{"rendered":"https:\/\/thermadormiami.support\/error-codes\/signal-sensor-error-refrigeration\/"},"modified":"2026-08-28T15:42:25","modified_gmt":"2026-08-28T15:42:25","slug":"senal-error-de-sensor-nevera","status":"publish","type":"error_code","link":"https:\/\/thermadormiami.support\/es\/error-codes\/signal-sensor-error-refrigeration\/","title":{"rendered":"C\u00f3digo de error de la nevera Thermador: mensaje de error del sensor"},"content":{"rendered":"<h1>C\u00f3digo de error de la nevera Thermador: mensaje de error del sensor<\/h1>\n<h3>Qu\u00e9 significa este c\u00f3digo<\/h3>\n<p>The column has found something wrong with itself and is asking to be tested rather than naming a part. This is a code without a number: the refrigeration columns have no display to put one on, so the appliance signals it instead. This make publishes no numeric codes for its refrigeration at all, and what this one means comes from the manufacturer&#8217;s own documentation rather than from us.<\/p>\n<h3>C\u00f3mo se ve en la pantalla<\/h3>\n<p>Aqu\u00ed no hay un n\u00famero que anotar, as\u00ed que esto es lo que debe buscar:<\/p>\n<ul>\n<li><strong>Un mensaje de error en la pantalla con el s\u00edmbolo ALARM encendido<\/strong><\/li>\n<\/ul>\n<h3>Qu\u00e9 la activa<\/h3>\n<p>Una alarma es amplia a prop\u00f3sito: le dice que el gabinete not\u00f3 algo, no qu\u00e9 pieza es la responsable. Esta se activa por:<\/p>\n<ul>\n<li>Un sensor de temperatura en uno de los compartimentos<\/li>\n<li>El cableado de regreso al control<\/li>\n<li>La tarjeta de control<\/li>\n<\/ul>\n<h3>Qu\u00e9 puede probar usted mismo<\/h3>\n<ol>\n<li>Haga la autoprueba del aparato: apague la columna, espere cinco minutos, enci\u00e9ndala con la puerta cerrada y luego mantenga presionados SETUP y ALARM OFF juntos durante cinco segundos<\/li>\n<li>Mire los mensajes de diagn\u00f3stico hasta el final: si termina mostrando la temperatura programada, no encontr\u00f3 nada<\/li>\n<\/ol>\n<h3>Y despu\u00e9s<\/h3>\n<p>La autoprueba es la raz\u00f3n por la que vale la pena hacer esto antes de llamar: toma unos minutos y aclara si la columna tiene un problema real o lo report\u00f3 una sola vez. Si termina con el s\u00edmbolo ALARM y un mensaje, anote el mensaje: eso es lo que necesita un t\u00e9cnico.<\/p>\n<p>Este aparece en neveras &amp; columnas empotradas y columnas de freezer. <a href=\"https:\/\/thermadormiami.support\/es\/codigos-de-error\/\">La lista completa de c\u00f3digos<\/a> tiene el resto.<\/p>\n<p>Neveras empotradas &amp; columnas<\/p>\n<p>Qu\u00e9 significa este c\u00f3digo<\/p>\n<p>Qu\u00e9 significa este c\u00f3digo<br \/>\nThe column has found something wrong with itself and is asking to be tested rather than naming a part. This is a code without a number: the refrigeration columns have no display to put one on, so the appliance signals it instead. This make publishes no numeric codes for its refrigeration at all, and what this one means comes from the manufacturer&#8217;s own documentation rather than from us.<br \/>\nC\u00f3mo se ve en la pantalla<br \/>\nAqu\u00ed no hay un n\u00famero que anotar, as\u00ed que esto es lo que debe buscar:<\/p>\n<p>Un mensaje de error en la pantalla con el s\u00edmbolo ALARM encendido<\/p>\n<p>Qu\u00e9 la activa<br \/>\nUna alarma es amplia a prop\u00f3sito: le dice que el gabinete not\u00f3 algo, no qu\u00e9 pieza es la responsable. Esta se activa por:<\/p>\n<p>Un sensor de temperatura en uno de los compartimentos<br \/>\nEl cableado de regreso al control<br \/>\nLa tarjeta de control<\/p>\n<p>Qu\u00e9 puede probar usted mismo<\/p>\n<p>Haga la autoprueba del aparato: apague la columna, espere cinco minutos, enci\u00e9ndala con la puerta cerrada y luego mantenga presionados SETUP y ALARM OFF juntos durante cinco segundos<br \/>\nMire los mensajes de diagn\u00f3stico hasta el final: si termina mostrando la temperatura programada, no encontr\u00f3 nada<\/p>\n<p>Y despu\u00e9s<br \/>\nLa autoprueba es la raz\u00f3n por la que vale la pena hacer esto antes de llamar: toma unos minutos y aclara si la columna tiene un problema real o lo report\u00f3 una sola vez. Si termina con el s\u00edmbolo ALARM y un mensaje, anote el mensaje: eso es lo que necesita un t\u00e9cnico.<br \/>\nThis one appears on built-in refrigerators &amp; columns and freezer columns. The full list of codes has the rest.<\/p>","protected":false},"excerpt":{"rendered":"<p>Thermador error code, the kind with no number: sensor error message \u2014 the column has found something wrong with itself and is asking to be tested rather than naming a part. What it covers, what to check first, and what it does not tell you, on built-in refrigerators &#038; columns and freezer columns.<\/p>","protected":false},"menu_order":67,"template":"","appliance_type":[30,31],"product_line":[],"class_list":["post-415","error_code","type-error_code","status-publish","hentry","appliance_type-refrigerator","appliance_type-freezer"],"acf":[],"_links":{"self":[{"href":"https:\/\/thermadormiami.support\/es\/wp-json\/wp\/v2\/error_code\/415","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/thermadormiami.support\/es\/wp-json\/wp\/v2\/error_code"}],"about":[{"href":"https:\/\/thermadormiami.support\/es\/wp-json\/wp\/v2\/types\/error_code"}],"wp:attachment":[{"href":"https:\/\/thermadormiami.support\/es\/wp-json\/wp\/v2\/media?parent=415"}],"wp:term":[{"taxonomy":"appliance_type","embeddable":true,"href":"https:\/\/thermadormiami.support\/es\/wp-json\/wp\/v2\/appliance_type?post=415"},{"taxonomy":"product_line","embeddable":true,"href":"https:\/\/thermadormiami.support\/es\/wp-json\/wp\/v2\/product_line?post=415"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}